Handheld type Ultrasonic Flow Meter
Handheld type Ultrasonic Flow Meter
Model
CSDS - 100H
Application
● Tap water
● Heating
● Water conservancy
● Metallurgy chemical
● Machinery
● Energy
Specification
● No-contact measurement of liquid flow
● Small size, convenient carrying
Standard design
Linearity | 0.5% |
Repeatability | 0.2% |
Accuracy | 士1% (rates > 0.2 mps) |
Response Time | 0 - 999 seconds, user - configurable |
Pipe Size | DN15 - 6000mm |
Rate Units | Meter, Feet, Cubic Meter, Liter, Cubic Feet, USA Gallon, Imperial Gallon, Oil Barrel, USA Liquid Barrel, Imperial Liquid Barrel, Million USA Gallons. Users configurable |
Totalizer | 7-digit totals for net, positive and negative flow respectively |
Liquid Types | Virtually all liquids |
| Security | Setup values Modification Lockout. Access code needs unlocking |
| Display | 4x8 Chinese characters or 4x16 English letters |
| Communication Interface | RS-232C, baud-rate: from 75 to 57600. Protocol made by the manufacturer and compatible with that of the FUJI ultrasonic flow meter. User protocols can customized. |
| Transducers | Model M1 |
| Transducer Cord Length | 2x5 meters optional: 2x 10 meters |
| Power Supply | 3 AAA Ni-H built-in batteries. When fully recharged it will last over 10 hours of operation.100V-240VAC for the charger |
| Data Logger | Built-in data logger can store over 2000 lines of data |
| Manual Totalizer | 7-digit press-key-to-go totalizer for calibration |
| Housing Material | ABS |
| Case Size | 100x66x20mm |
| Handset Weight | 514g (1.2 lbs) with batteries |
Installation Requirement
The state of the pipeline for measuring the flow will greatly affect the measurement accuracy, the detector installation location should be selected in a place that meets the following conditions:
1. It must be ensured that the straight pipe section where the probe is installed is: 10D on the upstream side(D is the pipe diameter), 5D or more on the downstream side, and there must be no factors that disturb the fluid(such as pumps,valves, throttles, etc.) in the 30D on the upstream side. And try to avoid the unevenness and welding position of the pipeline under test.
2. The pipeline is always full of liquid, and the fluid should not contain bubbles or other foreign objects. For horizontal pipelines, install the detector within ±45°of the horizontal centerline. Try to choose the horizontal centerline position.
3. When install the ultrasonic flow meter, need to input these parameters: pipe material,pipe wall thickness and pipe diameter. Fulid type, whether it contains impurities,bubbles, and whether the tube is full.