Bimetal thermometer, Stainless steel
For industrial applications
Bimetal thermometer For industrial applications
Model
TC01.010 bottom connection
TC02.050 back connection
TC03.050 Any angle connection
TC02.050 back connection
TC03.050 Any angle connection
Applications
● A wide range of applications in machine building, vessel, piping and apparatus construction
● Heating technology
Special features
● Scale ranges from -30 ... +500 °C
● Large choice of nominal sizes from 25 ... 160 mm
● Case and stem from stainless steel
● 5 different connection designs
Specifications
Design | EN13190 |
Measuring element | Bimetal coil |
Nominal size in mm | 25, 33, 40, 50, 63, 80, 100, 160 |
Connection design | S, standard(male threaded connection) 1, plain stem(without thread) 2, male nut 3, union nut 4, compression fitting(sliding on stem) other connection designs on request |
Unit(Scale range) | °C Option: ■ °F ■ °C/°F (dual scale) ■ °F/°C (dual scale) |
Process connection | ■ Plain, without thread ■ G ½ B ■ ½ NPT ■ G ½ female ■ ½ NPT female ■ M20 x 1.5 ■ M24 x 1.5 female others on request |
Accuracy class | NS25, 33 : ±5% of scale range NS40, 50 : 2 per EN 13190 NS63, 80, 100, 160: 1 per EN13190 |
Working rang | Continuous load Measuring rang per EN13190 Short time(max. 24h) Scale range per EN13190 |
Stem diameter | 6.35 mm Option: ■ 6 mm ■ 8 mm ■ 10 mm ■ 12 mm Others on request |
Insertion length L1 | 63 ... 1,000 mm Minimum/maximum length is dependent on the measuring range and diameter |
Case, ring, stem, process connection and spacer | Stainless Steel 304 Option: Stainless steel 316L |
Window | Instrument glass NS 33 : PC |
Wetted materials | Stem, process connection Stainless steel 304 Option: Stainless steel 316L |
Dial | Aluminium white, black lettering |
Pointer | Aluminium, black |
Permissible operation press at stem | NS25, 33, 40, 50: max. 6 bar, static NS63, 80, 100, 160: max. 25 bar, static |
Ingress protection | NS25, 33, 40: IP54 per IEC 60259 NS50, 63, 80, 100, 160: IP43 per IEC 60259 |
Scale and measuring range (EN13190)
Scale graduation per CSHERUN standard
Scale range in ℃ | Measuring range in ℃ | Scale spacing in ℃ |
-40 … +60 | -30 … +50 | 1 |
-40 … +80 | -30 … +60 | 2 |
-40 … +160 | -30 … +140 | 2 |
-30 …+50 | -20 …+40 | 1 |
-30 …+70 | -20 …+60 | 1 |
-20… +60 | -10… +50 | 1 |
-20… +80 | -10… +70 | 1 |
-20… +100 | 0… +80 | 2 |
-20… +120 | 0… +100 | 2 |
-20… +140 | 0… +120 | 2 |
-10… +50 | 0… 40 | 1 |
0 … 60 | 10 … 50 | 1 |
0 … 80 | 10 …70 | 1 |
0 … 100 | 10 … 90 | 1 |
0 … 120 | 10 … 110 | 2 |
0 … 150 | 20 … 130 | 2 |
0 … 160 | 20 … 140 | 2 |
0 … 200 | 20 … 180 | 2 |
0 … 250 | 30 … 220 | 2 |
0 … 300 | 30 … 270 | 5 |
0 … 400 | 50 … 350 | 5 |
0 … 500 | 50 … 450 | 5 |
0 … 600 | 100 … 500 | 5 |
Connection design





Dimensions in mm


Model / Nominal size / Scale range / Connection size / Connection location / Options