Bimetal thermometer, Stainless steel
For the process industry per EN 13190
Model
TB01.010 bottom connection
TB01.030 bottom connection with liquid filling
TB02.050 back connection
TB02.070 bottom connection with liquid filling
TB03.050 Any angle connection
TB03.070 bottom connection with liquid filling
TB01.030 bottom connection with liquid filling
TB02.050 back connection
TB02.070 bottom connection with liquid filling
TB03.050 Any angle connection
TB03.070 bottom connection with liquid filling
Applications
● General process instrumentation in the chemical and petrochemical industries, oil and gas industries, energy and water/waste water industries
● Temperature measurement in harsh and aggressive environment
Special features
● Scale ranges from -60 ... +600 °C
● For extreme ambient temperatures
● Maintenance-friendly bayonet case
● All stainless steel construction
● Individual stem length from 63 ... 1,000 mm
Specifications
Design | EN13190 |
Measuring element | Bimetal coil |
Nominal size in mm | 63, 100, 160 |
Connection design | S, standard(male threaded connection) 1, plain stem(without thread 2, male nut 3, union nut 4, compression fitting(sliding on stem) 5, union nut and loose threaded connection |
Adjustable stem and dial” case version | Swivelling 90° and rotatable 360° |
Unit(Scale range) | °C Option: ■ °F ■ °C/°F (dual scale) ■ °F/°C (dual scale) |
Process connection | ■ Plain, without thread ■ G ½ B ■ ½ NPT ■ G ½ female ■ ½ NPT female ■ M20 x 1.5 ■ M24 x 1.5 female others on request |
Accuracy | Class 1 per EN13190 |
Working rang | Continuous load(1 year) Measuring rang(EN13190) Short time(max. 24h) Scale range(EN13190) |
Stem diameter | 6.35 mm Option: ■ 6 mm ■ 8 mm ■ 10 mm ■ 12 mm Others on request |
Insertion length L1 | 63 ... 1,000 mm Minimum/maximum length is dependent on the measuring range and diameter |
Window | Instrument glass NS 63: window from polycarbonate Option: Laminated safety glass, clear non-splintering plastic |
Zero adjustment (option) | On case back side, external only for adjustable stem and dial |
Damping | Without Option: With glycerine/silicone oil case filling, up to max. 250 °C (at the probe) |
Wetted materials | Stem, process connection Stainless steel 304SS option: stainless steel 316L |
Non-wetted materials | Case, bayonet ring Stainless steel 304SS (option: stainless steel 316L) |
Dial | Aluminium white, black lettering |
Pointer | Aluminium, black |
Ingress protection per IEC/EN 60529 | IP65 Option: ■ IP66 ■ IP67 |
Permissible temperatures | Ambient (at the case) -40 ... +70 °C (with/without filling liquid) Option: ■ -50 ... +70 °C ■ -70 ... +60 °C |
Storage and transport | -50 … +70 °C |
Permissible operating pressure at the stem | max. 25 bar, static |
Scale and measuring range (EN13190)
Scale range in ℃ | Measuring range in ℃ | Scale spacing in ℃ |
-40 … +60 | -30 … +50 | 1 |
-40 … +80 | -30 … +60 | 2 |
-40 … +160 | -30 … +140 | 2 |
-30 …+50 | -20 …+40 | 1 |
-30 …+70 | -20 …+60 | 1 |
-20… +60 | -10… +50 | 1 |
-20… +80 | -10… +70 | 1 |
-20… +100 | 0… +80 | 2 |
-20… +120 | 0… +100 | 2 |
-20… +140 | 0… +120 | 2 |
-10… +50 | 0… 40 | 1 |
0 … 60 | 10 … 50 | 1 |
0 … 80 | 10 …70 | 1 |
0 … 100 | 10 … 90 | 1 |
0 … 120 | 10 … 110 | 2 |
0 … 150 | 20 … 130 | 2 |
0 … 160 | 20 … 140 | 2 |
0 … 200 | 20 … 180 | 2 |
0 … 250 | 30 … 220 | 2 |
0 … 300 | 30 … 270 | 5 |
0 … 400 | 50 … 350 | 5 |
0 … 500 | 50 … 450 | 5 |
0 … 600 | 100 … 500 | 5 |
Connection designs
Dimensions in mm
Adjustable stem and dial version
Model / Nominal size / Scale range / Connection size / Connection location / Options